JAMA Ophthalmology·September 24Open Access
OphthalmologyPractice changingBlepharoptosisProspective Diagnostic/Prognostic StudyArtificial Intelligence Diagnostic ToolSmartphone-Based 3D ReconstructionMixed

Summary

View source

What was studied

This prospective multicenter study (5 hospitals, 2025) evaluated the Digital Rulers of Ptosis (DRP), a smartphone-based 3D reconstruction app, for automated measurement of marginal reflex distance 1 (MRD1) and levator function (LF) in 952 participants (1,904 eyes, ages 3–86), comparing it to same-day oculoplastic specialist measurements as the reference standard.

Key findings

DRP showed high agreement with specialist measurements (MRD1 MAE 0.52 mm, ICC 0.93; LF MAE 0.95 mm, ICC 0.95), achieved AUC 0.97 for ptosis diagnosis and AUC 0.98 for surgical approach classification, and outperformed a 2D deep-learning baseline (ΔAUC ~0.07–0.09); postoperative recurrence at 3 months was 7.3% (18/248 eyes), lower than the 14–63% reported in prior literature.

Study limitations

Postoperative recurrence was only assessed at 3 months without a randomized comparison to conventional care; specialist manual measurements used as the reference standard carry inherent interobserver variability; the study cohort was predominantly from China, limiting ethnic generalizability.

Clinical implications

A 10-second smartphone video using the DRP app can reliably quantify MRD1 and levator function with near-specialist accuracy, offering a practical tool for ptosis screening, preoperative planning, and remote follow-up—particularly in settings without oculoplastic specialists. Regulatory approval is still pending before clinical commercial use.

Caveats

  • Children under 6 years (21.6% of eyes) and older adults with skin laxity represent subgroups where video acquisition and measurement reliability are inherently more challenging
  • Postoperative outcomes were assessed at 3 months only and were not randomized; whether DRP-guided planning independently reduces recurrence is unknown
  • Specialist manual measurement served as the reference standard but is itself subject to interobserver variability, potentially underestimating true DRP accuracy
Show all 4
  • Study population was recruited exclusively from hospitals in China (predominantly one center), which may limit generalizability to ethnically diverse or lower-resource settings

Related Questions

Explore related topics

Smartphone AI tools for eyelid measurement and ptosis diagnosis accuracyMarginal reflex distance 1 and levator function measurement methods in blepharoptosisPostoperative recurrence rates after congenital and acquired ptosis surgery

Publication Details

Year
2026
Journal
JAMA Ophthalmology
Sample Size
n=952