This systematic review and meta-analysis evaluated the effects of CFTR modulator therapy on aerobic fitness in people with cystic fibrosis (pwCF), using cardiopulmonary exercise testing (CPET) outcomes — primarily peak VO₂ — across 13 studies (n=578, mean age 9.1–42.0 years, modulator duration 6–208 weeks).
CFTR modulators did not significantly improve peak VO₂ (MD = −0.22 mL·kg⁻¹·min⁻¹; 95% CI: −2.10 to 1.65; p=0.82; I²=79%). However, breathing reserve improved (MD = +7.94%; p=0.007) and maximal workload increased (MD = +15.39 W; p=0.02). After sensitivity analysis, VO₂ at the first ventilatory threshold (VT1) was modestly but significantly lower post-therapy (MD = −1.85; p<0.00001), though clinical relevance is uncertain.
- Most studies were observational with small samples and short follow-up; two case series had only 3 participants each, limiting precision. - High heterogeneity for peak VO₂ (I²=79%) and workload (I²=87%) reduces confidence in pooled estimates. - Mixed modulator types, CPET protocols, and patient characteristics (age, disease severity, physical activity level) limit direct comparisons; publication bias was not formally assessed.
Clinicians should not expect CFTR modulators alone to meaningfully boost peak VO₂ — structured exercise training likely remains essential for aerobic gains. Submaximal CPET metrics (breathing reserve, workload) may capture functional improvements missed by peak VO₂ alone and are worth tracking after modulator initiation.