This nationwide retrospective cohort study examined how often capnometry (EtCO₂ monitoring) was used during prehospital endotracheal intubations in Denmark from 2016–2021 (n=8,625 patients), and whether its use was associated with 30-day mortality.
Capnometry was used in 80.3% of cases and rose from 75.4% (2016) to 82.6% (2021). Its use was independently tied to lower 30-day mortality (adjusted OR 0.52, 95% CI 0.46–0.60). Overall 30-day mortality was 62.6%; patients without capnometry had 74.8% mortality vs. 59.6% with it. Hypocapnia (EtCO₂ <4.0 kPa) was the most common abnormality (38.3%) and carried the highest mortality (70.4%; adjusted OR 2.67, 95% CI 2.20–3.24). Only 10.1% of monitored patients had normal EtCO₂ values, and their mortality was lowest at 36.7%.
Observational design prevents causal inference — capnometry use may be a marker of better overall care rather than a direct cause of survival benefit. EtCO₂ was defined by any recorded value >0, which may not capture full or continuous monitoring. Data are limited to Denmark and a single registry, which may restrict generalizability.
Routine EtCO₂ monitoring after every prehospital intubation is still not universal — nearly 1 in 5 patients went without it — and skipping it was linked to significantly worse survival. Clinicians should also treat abnormal EtCO₂ values, especially hypocapnia, as urgent red flags requiring immediate ventilation adjustment.