Convergent validity among five measures of daily functioning in 237 older adults (mean age 74.8 years): two subjective scales (ADCS-ADL-MCI 23-item and Quick Dementia Rating System) and three performance-based measures (Independent Living Scales, Night-Out Task, Virtual Kitchen Challenge).
All five functional measures showed small-to-medium but statistically significant correlations with each other (rs = 0.21 to 0.61, p < 0.01); factor analysis identified three factors organized by scoring type (correct/incorrect vs. timed) and assessment method (subjective vs. performance-based).
Sample was relatively small (n=237), highly educated (mean 16.9 years), and likely not diverse; only five functional scales were examined, limiting generalizability to other instruments.
Clinicians can use subjective or performance-based daily functioning measures with some confidence that they tap the same underlying construct, but should be aware that scoring method and assessment type introduce distinct measurement dimensions that may capture different information.