A waterborne outbreak of *Mycobacterium abscessus* in a UK specialist cardiothoracic hospital (2019–2026) was investigated using whole genome sequencing (WGS) of clinical and environmental samples, epidemiological case-control analysis, and assessment of infection control interventions in lung transplant recipients, cystic fibrosis (CF), and non-CF bronchiectasis patients.
40 outbreak cases were identified over 7 years (11 lung transplant recipients, 11 CF, 14 non-CF bronchiectasis, 4 other); 19 developed NTM pulmonary disease. Point-of-use filters and biocide treatment reduced incidence from 12.8 to 2.2 cases per year, but no specific procedural risk factors (surgery or bronchoscopy) were identified. No new cases occurred after June 2025, coinciding with enhanced water flushing.
Case-control study may have been underpowered to detect procedural risk factors given the relatively small number of transplant cases. The outbreak strain persisted in the hospital water system despite extensive control measures, limiting confidence that elimination is permanent. Findings are from a single highly specialist centre, which may limit generalisability.
Hospitals housing vulnerable patients (transplant, CF, bronchiectasis) should implement robust water safety plans including point-of-use filters, biocide treatment, and enhanced flushing protocols, particularly when relocating to new buildings. WGS is essential to link clinical and environmental isolates and define outbreak extent.