American Journal of Obstetrics and Gynecology·October 8
Obstetrics & GynecologyConfirms priorIntrauterine Device InsertionProcedural PainRandomized Controlled TrialTranscutaneous Electrical Nerve StimulationAdultCuT380ALevonorgestrel 52 Mg IUD

Summary

View source

What was studied

Whether high-frequency TENS reduces pain during IUD insertion (LNG 52 mg or CuT380A) compared with sham TENS, measured by 100-mm VAS at the time of insertion, in a double-blind RCT of 98 participants enrolled March 2024–April 2025.

Key findings

Active TENS did not reduce insertion pain vs. sham (50.8 ± 26.9 mm vs. 50.6 ± 29.2 mm; p=0.97), with no effect in either nulliparous or parous subgroups; clinicians consistently underestimated participant pain (48.9 vs. 60.5 mm; p<0.001), and difficult insertions were associated with higher pain scores (71.6 vs. 56.0 mm; p=0.006).

Study limitations

Single-site trial with a relatively small sample (n=98) powered to detect only a 20 mm VAS difference, limiting detection of smaller but potentially meaningful effects; study did not evaluate other TENS frequencies or electrode placements that might perform differently.

Clinical implications

High-frequency TENS should not be offered as a pain-reduction strategy for IUD insertion. Clinicians should be aware they routinely underestimate patient pain during this procedure, and difficult insertions warrant extra attention to patient comfort.

Caveats

  • Clinicians significantly underestimated participant pain scores (mean 48.9 mm vs. patient-reported 60.5 mm), suggesting a systematic perception gap that may affect post-procedure care assessments
  • Findings apply specifically to high-frequency TENS; other TENS parameters or electrode placements were not tested and may yield different results
  • The trial was powered to detect a 20 mm VAS difference; smaller but clinically meaningful effects cannot be ruled out

Related Questions

Explore related topics

What pain management options are effective for IUD insertion?Why do clinicians underestimate patient pain during gynecologic procedures?Does parity predict pain severity during IUD insertion?

Publication Details

Year
2026
Journal
American Journal of Obstetrics and Gynecology
Sample Size
n=98
Source
View article
Keep scrolling