ReachRxResearch
Home
Research
Sign Up
Real-time feedback during bag-valve-mask ventilation for out-of-hospital cardiac arrest: a before-and-after study (VEntilation during Cardiac Arrest Resuscitation Study, VECARS-2)
Back to Research Hub
  1. Home
  2. Research Hub
  3. Real-time feedback during bag-valve-mask…

Real-time feedback during bag-valve-mask ventilation for out-of-hospital cardiac arrest: a before-and-after study (VEntilation during Cardiac Arrest Resuscitation Study, VECARS-2)

Resuscitation·October 20
Emergency MedicineLimited evidenceOut-Of-Hospital Cardiac ArrestBefore-And-After StudyBag-Valve-Mask VentilationReal-Time Feedback DeviceAdult

Summary

View source

What was studied

Whether real-time feedback during bag-valve-mask ventilation improves adherence to guideline-recommended tidal volume (400–600 mL) in adults with out-of-hospital cardiac arrest managed by basic life support teams under 30:2 CPR, comparing two sequential cohorts (96 without feedback vs. 67 with feedback).

Key findings

Real-time feedback improved insufflated volume (Vi) adherence to the 400–600 mL range (68% vs. 42%) and reduced Vi dispersion by 35%, but expiratory tidal volume (Vt) adherence was nearly unchanged (14% vs. 15%), and median Vt was not significantly different (235 vs. 243 mL); leak volume was 12% lower with feedback (mean ratio 0.88, 95% CI 0.77–0.99).

Study limitations

Before-and-after design cannot establish causation; Vt remained well below guideline targets in both periods, suggesting large mask leaks that feedback did not correct; findings from a single Paris Fire Brigade BLS system may not generalize to other EMS settings.

Clinical implications

Real-time ventilation feedback helps rescuers squeeze the bag more consistently within target range, but clinicians should know that most of that volume never reaches the patient due to mask leak — improving Vi alone is unlikely to be enough without also addressing mask seal.

Caveats

  • Expiratory tidal volume remained far below the 400–600 mL guideline target in both periods (≈235–243 mL), indicating large and persistent mask leaks that feedback did not meaningfully correct — the clinical benefit of improving insufflated volume alone is uncertain
  • The before-and-after design with sequential (non-concurrent) cohorts introduces risk of confounding by secular trends, changes in team training, or patient-mix differences between periods
  • The study was conducted exclusively with Paris Fire Brigade basic life support teams; results may not apply to ALS crews, other EMS systems, or different rescuer skill levels

Related Questions

Explore related topics

Real-time CPR feedback devices for ventilation quality in out-of-hospital cardiac arrestMask leak during bag-valve-mask ventilation in cardiac arrest resuscitationTidal volume targets and outcomes in CPR 30:2 ventilation protocols

Publication Details

Year
2026
Journal
Resuscitation
Sample Size
n=163
Source
View article
Keep scrolling
More content below.
Up Next