ReachRxResearch
Home
Research
Sign Up
Artificial intelligence and digital technologies transforming neonatal respiratory assessment: a scoping review
Back to Research Hub
  1. Home
  2. Research Hub
  3. Artificial intelligence and digital tech…

Artificial intelligence and digital technologies transforming neonatal respiratory assessment: a scoping review

Journal of Perinatology·October 2Open Access
Obstetrics & GynecologyLimited evidenceBronchopulmonary DysplasiaNeonatal Respiratory Distress SyndromeScoping ReviewArtificial Intelligence / Machine LearningChest RadiographyDeep LearningDigital AuscultationElectronic Health RecordsLung UltrasoundNeonate

Summary

View source

What was studied

This scoping review mapped 35 studies (2019–2026) on the use of digital technologies and AI — including machine learning, deep learning, imaging analysis, and continuous monitoring — for neonatal respiratory assessment in the NICU.

Key findings

AI approaches showed promise across three main areas: predictive models (e.g., BPD, mechanical ventilation need), medical image analysis (chest X-ray, lung ultrasound with deep learning), and continuous physiological monitoring — but no technology was ready for widespread clinical implementation due to methodological heterogeneity, small samples, and lack of external validation.

Study limitations

Most included studies were single-center, retrospective, or small-sample; external validation was rare; and there was no standardization of protocols across studies, making cross-study comparisons unreliable.

Clinical implications

Clinicians should view AI-based neonatal respiratory tools as research-stage only — promising for early identification of BPD, ventilation need, and RDS, but requiring prospective, multicenter validation before routine use.

Caveats

  • Included studies span highly heterogeneous designs, populations, and AI methods — pooled conclusions are descriptive only and should not be interpreted as quantitative meta-analytic findings
  • Most underlying studies lack external validation; findings from individual models may not generalize across NICUs, countries, or scanner types
  • Several studies included very small sample sizes (as low as N=19–23), limiting the reliability of reported model performance metrics